18/05/12 Cu: 7795$ 6128€
SC4Z1-K (AS+) 0,6/1kV PDF Print E-mail

Description

SC4Z1-K (AS+) 0,6/1kV

sc4z1-k_as_web.jpg

 

Description


These cables are indicated for executing permanent installations where fire resistance is required as well as electromagnetic protection to avoid parasitic currents. They are useful for control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, temperature, intensity or voltage regulation in motorised valves as well as for installations in computer centres, airports, road tunnels, railways and anywhere where low fumes and corrosive gas emission is required in the cade of fire, such as public premises, hospitals, schools and shopping centres.

Applications


  • Public premises

Appropriate for installations where greater fire protection is required and to guarantee the working of installations directly subject to fire, for 90 minutes at 400ºC.

 

industrial.gif
flexible.gif 90.gif iman.gif

as+.gif

400.gif

Technicals Characteristics

SC4Z1-K (AS+) 0,6/1kV

 

sc4z1construccion.jpg
sc4z1detalle.jpg

 

1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.
2. Insulation

Silicone insulation, type EI-2, according to UNE 50363.

3. Screen

70% copper braid on polyester sheet

4.Sheathing

Thermoplastic polyolefin sheath according to UNE 21123.

Rated voltage

0,6/1kV

Test voltage

3.500V in C.A.

Maximum temperature

90ºC

Other charateristics
  • Colours according to UNE 21089 and HD 303S2:2001
  • Fire resistance according to UNE-EN 50200, EN 50200, UNE-EN 50362 and EN
  • 50362
  • Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
  • Non-fire propagating according to UNE-EN 50266 and EN 50266
  • Low halogen content according to UNE-EN 50267 and EN 50267
  • Low corrosive gas emission according to UNE-EN 50267 and EN 50267
  • Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034

National norm / european

EN 60332-1 / EN 50266 / EN 50267-1 / EN 50267-2 / EN 61034 / UNE-EN 50200 / UNE-EN 50363
International norm
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034

Dimensions

SC4Z1-K (AS+) 0,6/1kV

 

 

Section (mm2) Resistantce at 20ºC
(
Ω/km)
External Diameter (mm) Weight (kg/km) Section
(mm2)
Resistance at 20ºC
(Ω/Km)
External Diameter
(mm)
Weight
(kg/km)
1x1,5 13,30 7,49 70 3x4 4,95 11,80 265
1x2,5 7,98 8,04 84 3x6 3,30 13,50 360
1x4 4,95 8,74 104 3x10 1,91 15,20 495
1x6 3,30 9,46 132 3x16 1,21 17,60 594
1x10 1,91 11,90 231 3x25 0,780 21,20 872
1x16 1,21 13,10 300 3x35 0,554 24,40 1.195
1x25 0,780 14,20 389 4x1,5 13,30 10,60 185
1x35 0,554 15,30 489 4x2,5 7,98 11,60 240
1x50 0,386 16,80 637 4x4 4,95 12,70 324
1x70 0,272 18,70 835 4x6 3,30 14,60 430
1x95 0,206 21,10 1.098 4x10 1,91 16,60 605
1x120 0,161 22,60 1.331 4x16 1,21 18,70 855
1x150 0,129 24,70 1.628 4x25 0,780 22,80 1.330
1x185 0,106 26,90 1.975 4x35 0,554 24,40 1.740
1x240 0,0801 30,00 2.514 4x50 0,386 29,30 2.370
1x300 0,0641 33,20 3.114 4x70 0,272 35,00 2.804
1x400 0,0486 40,80 4.600 4x95 0,206 40,20 3.741
2x1,5 13,30 9,50 145 5x1,5 13,30 11,10 205
2x2,5 7,98 10,30 180 5x2,5 7,98 12,20 280
2x4 4,95 11,30 225 5x4 4,95 13,30 324
2x6 3,30 12,80 300 5x6 3,30 15,10 441
2x10 1,91 14,40 410 5x10 1,91 19,80 815
2x16 1,21 16,30 436 5x16 1,21 21,50 928
2x25 0,780 19,50 646 5x25 0,780 25,70 1.387
3x1,5 13,30 9,90 165 5x35 0,554 29,80 1.905
3x2,5 7,98 10,80 205


Documents

SC4Z1-K (AS+) 0,6/1kV