18/05/12 Cu: 7795$ 6128€
SZ1C4Z1-K (AS+) 0,6/1kV PDF Print E-mail

Description

SZ1C4Z1-K (AS+) 0,6/1kV

sz1c4z1-k_as_01_web.jpg

Description


These cables are indicated for executing permanent installations where fire resistance is required as well as electromagnetic protection to avoid parasitic currents. They are useful for control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, temperature, intensity or voltage regulation in motorised valves as well as for installations in computer centres, airports, road tunnels, railways and anywhere where low fumes and corrosive gas emission is required in the case of fire, such as public premises, hospitals, schools and shopping centres.

Applications


  • Public premises

Appropriate for installations where greater fire protection is required and to guarantee the operation of installations directly subject to fire, for 90 minutes at 400ºC.

 

industrial.gif flexible.gif 90.gif

as+.gif

iman.gif

400.gif

 

 

Technical Charcteristics

SZ1C4Z1-K (AS+) 0,6/1kV

 

sz1c4z1construccion.jpg
sz1c4z1detalle.jpg

 

1. Conductor

Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insultaion

Silicone insulation, type EI-2, according to UNE-EN 50363.

3. Screen bedding

Thermoplastic Polyolefin.

4. Screen

70% copper braid on polyester sheet.

5. Sheathing

Thermoplastic polyolefin sheath according to UNE 21123

Rated voltage

0,6/1kV

Test voltage

3.500V in A.C.

Maximum temperature

90ºC

Other characteristics
  • Colours according to UNE 21089 and HD 303S2:2001
  • Fire resistance according to UNE-EN 50200, EN 50200, UNE-EN 50362 and EN 50362
  • Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
  • Non-fire propagating according to UNE-EN 50266 and EN 50266
  • Low halogen content according to UNE-EN 50267 and EN 50267
  • Low corrosive gas emission according to UNE-EN 50267 and EN 50267
  • Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034

National norm / european

EN 60332-1 / EN 50266 / EN 50267-1 / EN 50267-2 / EN 61034 / UNE-EN 50200 / UNE-EN 50363
International norm
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034

 

Dimensions

SZ1C4Z1-K (AS+) 0,6/1kV

 

Section (mm2) Resistance at 20ºC (Ω/Km) External Diameter (mm) Weight
(kg/km)
Section
(mm2)
Resistance at 20ºC
(Ω/Km)
External Diameter
(mm)
Weight
(kg/km)
1x1,5 13,30 7,97 105 3x4 4,95 12,48 271
1x2,5 7,98 8,52 121 3x6 3,30 13,88 348
1x4 4,95 9,22 144 3x10 1,91 16,18 494
1x6 3,30 9,94 176 3x16 1,21 18,08 675
1x10 1,91 12,38 286 3x25 0,780 21,68 970
1x16 1,21 13,58 360 3x35 0,554 24,88 1.307
1x25 0,780 14,68 454 4x1,5 13,30 10,78 188
1x35 0,554 15,78 559 4x2,5 7,98 11,68 235
1x50 0,386 17,28 714 4x4 4,95 13,58 335
1x70 0,272 19,18 921 4x6 3,30 15,28 423
1x95 0,206 21,58 1.195 4x10 1,91 17,58 608
1x120 0,161 23,08 1.435 4x16 1,21 19,98 845
1x150 0,129 25,18 1.742 4x25 0,780 22,98 1.183
1x185 0,106 27,38 2.099 4x35 0,554 26,18 1.624
1x240 0,0801 30,48 2.652 4x50 0,386 30,58 2.176
1x300 0,0641 33,68 3.267 4x70 0,272 35,48 2.966
1x400 0,0486 41,28 4.789 4x95 0,206 40,68 3.927
2x1,5 13,30 9,48 137 5x1,5 13,30 11,68 219
2x2,5 7,98 10,38 168 5x2,5 7,98 13,18 291
2x4 4,95 11,18 205 5x4 4,95 14,48 374
2x6 3,30 12,28 256 5x6 3,30 16,48 505
2x10 1,91 14,28 359 5x10 1,91 18,58 702
2x16 1,21 16,78 511 5x16 1,21 21,98 1.027
2x25 0,780 19,98 736 5x25 0,780 26,18 1.505
3x1,5 13,30 10,08 161 5x35 0,554 30,28 2.042
3x2,5 7,98 11,68 224



Documents

SZ1C4Z1-K (AS+) 0,6/1kV

 

pdflogo2.jpg