(+34) 976 500 120 | Contact us

Description


These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, schools, shopping centres and airports. The metal band provides greater protection against mechanical aggressions and the action of rodents. Their flexibility makes them very appropriate in complex and extremely difficult installations.

Reference Standards

UNE 21123, HD 603 S1 and IEC 60502

Applications

Suitable for the following installations:
  • Underground supply networks for outdoor lighting installations

They can also be used in the following applications:
  • Underground networks for low voltage distribution
  • Electricity distribution networks
  • Underground service connections
  • Installations in premises with special characteristics
  • Appropriate for installations where greater fire protection is required

Industrial Maximum temperature 90 ºC High Safety Anti rodent RoHS

Technical Characteristics

RZ1FAZ1 (AS) 0,6/1 kV RZ1FAZ1 (AS) 0,6/1 kV
1. Conductor

Rigid electrolytic copper conductor (Class I-II) according to UNE EN 60228, EN 60228 und IEC 60228

2. Insulation

Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1

3. Armour bedding

Thermoplastic polyolefin

4. Metallic armour

Double aluminium tape armour

5. Sheath

Thermoplastic polyolefin sheath according to UNE 21123

Nominal voltage

0,6/1 kV

Test voltage

3.500 V A.C.

Maximum temperature

90 ºC

Other characteristics

Colours according to UNE 21089 and HD 303S2 (colour marking when less than five conductors) and UNE-EN 50334 and EN 50334 (inscription marking when more than five conductors)
Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
Non-fire propagating according to UNE-EN 50266, EN 50266 and IEC 60332
Low halogen content according to IEC 60754-1 and 60754-2
Low corrosive gas emission according to IEC 60754-1 and 60754-2
Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
Using cross linked polyethylene (XLPE) allows a higher current density compared to the same section in PVC

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)

2x1,5

12,1

13,30

268

Documents

Newsletter

captcha 
I declare to be informed that I can exercise rights of access, rectification, cancellation and opposition by addressing RCT via email lopd@rct.es


By checking the box I acknowledge that I have read and I agree with the previous clause *

Newsletter 2

Los datos recogidos en el siguiente formulario los utilizaremos para enviar comunicaciones sobre nuestros productos o servicios. Usamos Elastic Email como nuestro servicio de Marketing Automation. Al enviar el formulario usted accede a que los datos entregados se transfieran a Elastic Email para ser procesados según sus términos de uso y política de privacidad.