(+34) 976 500 120 | Contact us

Description


These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, schools, shopping centres and airports. Electrical conductors of different colours and sections required to execute each installation are inserted onto the inside of a corrugated tube, thus achieving a product that provides the installer with an integral service that has numerous advantages and also saves time and costs.

Reference Standards

UNE-EN 50525-3-31, EN 50525-3-31, UNE 211002 and IEC

Applications

Suitable for the following installations:
  • Individual by-passIndoor or receiver installations
  • Public premisesInstallations in premises with fire or explosion risk
  • Appropriate for installations where increased fire protection is required

Domestic High Safety Super slide Flexible RoHS

Technical Characteristics

Tubo precableado H07Z1-K Type 2 Tubo precableado H07Z1-K Type 2
1. Conductor

Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insulation

Thermoplastic polyolefin insulation, type TI-7, according to UNE 211002 and HD 21.15S1:2006. With special properties against flame propagation, fire, opacity of fumes and corrosiveness of gases.

3. Tube

Tube, Corrugated fireproof polypropylene tube, with low halogen content, low fumes emission and non-flame propagating. Resistant to acids, bases and organic solvents and excellent compression properties (750N).

Nominal voltage

450/750 V

Test voltage

2.500 V A.C.

Maximum temperature

70 ºC

Other characteristics

Colours according to UNE-EN 50525-1 and EN 50525-1
Non-flame propagating according to UNE-EN 60332-1-2, EN 60332-1-2 and IEC 60332-1-2
Non-fire propagating in accordance with UNE-EN 60332-3-24, EN 60332-3-24 and IEC 60332-3-24
Low halogen content according to UNE 211002 Appendix A and HD 21.15S1:2006
Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
Low corrosive gas emission according to UNE 211002 Appendix A and HD |21.1S1:2006

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)

2x1,5

13,3

20,00

105

2x2,5

7,98

20,00

127

3x1,5

13,3

20,00

123

3x2,5

7,98

20,00

156

3x4

4,95

20,00

194

3x6

3,3

25,00

295

3x10 + 1,5

1,91

25,00

440

3x16 + 1,5

1,21

25,00

602

4x1,5

13,3

20,00

142

4x2,5

7,98

20,00

186

5x1,5

13,3

20,00

160

5x2,5

7,98

20,00

215

5x6

3,3

25,00

416

2x1,5 + 3x2,5

13,3

20,00

188

6x1,5

13,3

25,00

224

6x2,5

7,98

25,00

289

3x2,5 + 3x6

7,98

25,00

384

7x1,5

13,3

25,00

241

7x2,5

7,98

25,00

319

5x1,5 + 2x2,5

13,3

25,00

264

4x1,5 + 3x2,5

13,3

25,00

273

Newsletter

The data gathered through the next form will be used to send communications on our products and services. We use Elastic Email as our marketing automation service. By sending this form you agree with the transfer of the data to Elastic Email to be processed according to their terms of use and privacy policy.

Responsible: Cables RCT S.A.U. Purpose: To manage the submission of information and commercial prospecting. Legitimation: consent of the interested party. Recipients: Data will be transferred to Elastic Email for the automation of the submission. Rights: Access, correction and data erasure, as well as other rights, as explained in the additional information.Additional information on data protection is available on our website’s privacy policy