(+34) 976 500 120 | Contact us

Prewired tube H07Z1-K Type 2 (AS) CPR

Prewired tube H07Z1-K Type 2 (AS) CPR

Description


The H07Z1-K Type 2 (AS) CPR cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575 , being those indicated for fixed installations where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, schools, shopping centres and airports. Electrical conductors of different colours and sections required to execute each installation are inserted onto the inside of a corrugated tube, thus achieving a product that provides the installer with an integral service that has numerous advantages and also saves time and costs.

Reference Standards

UNE-EN 50525-3-31, EN 50525-3-31 and UNE 211002

Applications

Suitable for the following installations:
  • Individual by-passIndoor or receiver installations
  • Public premisesInstallations in premises with fire or explosion risk
  • Appropriate for installations where increased fire protection is required

Domestic High Safety Super slide Flexible Aenor Certificate HAR Certificate RoHS CPR rated

Technical Characteristics

Tubo precableado H07Z1-K Type 2 Tubo precableado H07Z1-K Type 2
1. Conductor

Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insulation

Thermoplastic polyolefin insulation, type TI-7, according to UNE 211002 and HD 21.15S1:2006. With special properties against flame propagation, fire, opacity of fumes and corrosiveness of gases.

3. Tube

Tube, Corrugated fireproof polypropylene tube, with low halogen content, low fumes emission and non-flame propagating. Resistant to acids, bases and organic solvents and excellent compression properties (750N).

Nominal voltage

450/750 V

Test voltage

2.500 V A.C.

Maximum temperature

70 ºC

Other characteristics

Colours according to UNE-EN 50525-1,EN 50525-1
Non-flame propagating according to UNE-EN 60332, EN 60332, IEC 60332
Non-fire propagating according EN 50399
Low halogen content according to UNE-EN 21031-15 Appendix A and HD 21.15S1:2006
Low corrosive gas emission according to UNE 21031 Appendix A0, HD 21.15S1:2006
Low opaque smoke emission according to UNE-EN 61034, EN 61034, IEC 61034

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)
Class

2x1,5

13,3

20,00

105

Cca- s1b, d1, a1

2x2,5

7,98

20,00

127

Cca- s1b, d1, a1

3x1,5

13,3

20,00

123

Cca- s1b, d1, a1

3G1,5

13,3

20,00

123

Cca- s1b, d1, a1

3x2,5

7,98

20,00

156

Cca- s1b, d1, a1

3x6

3,3

25,00

295

Cca- s1b, d1, a1

4x1,5

13,3

20,00

142

Cca- s1b, d1, a1

4x2,5

7,98

20,00

186

Cca- s1b, d1, a1

5x1,5

13,3

20,00

160

Cca- s1b, d1, a1

5x2,5

7,98

20,00

215

Cca- s1b, d1, a1

52x1,5

13,3

16,00

85

Cca- s1b, d1, a1

53x1,5

13,3

16,00

103

Cca- s1b, d1, a1

Documents

 
Previous versions 
Version From Until
013-03 17/07/2017 31/08/2017
013-02 09/02/2017 17/07/2017
013-01 24/11/2016 09/02/2017

Newsletter

The data gathered through the next form will be used to send communications on our products and services. We use Elastic Email as our marketing automation service. By sending this form you agree with the transfer of the data to Elastic Email to be processed according to their terms of use and privacy policy.

Responsible: Cables RCT S.A.U. Purpose: To manage the submission of information and commercial prospecting. Legitimation: consent of the interested party. Recipients: Data will be transferred to Elastic Email for the automation of the submission. Rights: Access, correction and data erasure, as well as other rights, as explained in the additional information.Additional information on data protection is available on our website’s privacy policy