Description


The Arctic Grade cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575.

These cables are designed to support severe climate conditions and to remain flexible at such low temperatures as -40 ºC. The plastic formulation for the Arctic Grade cables, manufactured according to standard BS6004, means that they remain flexible in extreme cold conditions, making them ideal for outdoor applications, where cable flexibility is a requirement at temperatures of below 0 ºC.


Reference Standards

BS 6004 table 6

Applications

Suitable for the following installations:
  • Installations at very low temperatures (-40ºC) where the cable must remain flexible.

Domestic Industrial Maximum temperature 70 ºC RoHS CPR rated

Technical Characteristics

Arctic Grade Arctic Grade
1. Conductor

Flexible electrolytic copper conductor (Class V) according to BS-EN 60228, UNE-EN 60228 and UNE 60228

2. Insulation

PVC Insulation type TI-4 according to BS-EN 50363-3, UNE-EN 50363-3 and EN 50363-3

3. Sheath

PVC type 10 according to BS 7655-4.2

Service temperature

-40/70 ºC

Nominal voltage

300/500 V

Test voltage

2.000 V A.C.

Other characteristics

Sheath colours: blue or yellow
Non-flame propagating according to UNE-EN 60332
CPR classification according to EN 50575

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)
Class

2x0,5

39

5,60

39

-

2x0,75

26

5,70

43

-

2x1

19,5

5,90

49

-

2x1,5

13,3

6,80

66

-

2x2,5

7,98

8,70

109

Eca

2x4

4,95

9,70

148

Eca

3G0,5

39

5,70

43

-

3G0,75

26

6,00

51

-

3G1

19,5

6,30

60

-

3G1,5

13,3

7,50

85

Eca

3G2,5

7,98

9,20

132

Eca

3G4

4,95

10,50

189

Eca

4x0,75

26

6,65

64

-

4x1

19,5

7,10

77

-

4x1,5

13,3

8,55

110

Eca

4x2,5

7,98

10,50

172

Eca

4x4

4,95

11,50

234

Eca

5x0,75

26

7,50

79

Eca

5x1

26

7,80

92

Eca

5x1,5

13,3

9,60

136

Eca

5x2,5

7,98

11,20

198

Eca

5x4

4,95

13,00

291

Eca