Description
These cables are indicated for executing permanent protected installations, electrical control panels and signal or control circuits.
Reference Standards
UNE-EN 50525-2-31, EN 50525-2-31 and IEC 60227-3
Applications
Suitable for the following installations:
- Outdoor lighting installations.
- EarthingIndoor or receiver installationsIndoor installations in housingIndoor installations in housing.
- Premises that contain a bath or shower
- Installations in premises with special characteristics
- Electrical installations in caravans and in caravans parks








Technical Characteristics


1. Conductor |
Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and EN 60228. |
---|---|
2. Insulation |
PVC insulation type TI-1 according to BS7655 and HD 21.3S3:1995/A2:2008. |
Nominal voltage |
300/500 V |
Test voltage |
2.000 V A.C. |
Maximum temperature |
70 ºC |
Other characteristics |
Colours according to HD 21.1S4:2002 |
Dimensions
Section (mm2) |
Resistance at 20 °C (Ohm/km) |
External Diameter (mm) |
Weight (kg/km) |
Class |
---|---|---|---|---|
1x0,5 |
39 |
2,15 |
9 |
Eca |
1x0,75 |
26 |
2,30 |
11 |
Eca |
1x1 |
19,5 |
2,50 |
14 |
Eca |
Documents
Previous versions | ||
---|---|---|
Version | From | Until |
026-03 | 17/07/2017 | |
026-02 | 17/07/2017 | 17/07/2017 |
026-01 | 15/02/2017 | 17/07/2017 |