(+34) 976 500 120 | Contact us

Description


These cables are indicated for executing permanent installations in housing, premises and offices, electrical control panels, as well as domestic and industrial lighting. They are easy to install thanks to their superslide insulation.


Reference Standards

UNE-EN 50525-2-31, EN 50525-2-31 and IEC 60227-3

Applications

Suitable for the following installations
  • Outdoor lighting installations
  • Earthing Indoor or receiver installations
  • Indoor installations in housing
  • Indoor installations in housing
  • Premises that contain a bath or shower
  • Installations on premises with fire or explosion risk
  • Installations in premises with special characteristics
  • Electrical installations in caravans and in caravans parks

 

Domestic Outdoor lighting Maximum temperature 70 ºC Super slide Aenor Certificate HAR Certificate RoHS CPR rated

Technical Characteristics

H07V-R H07V-R

1. Conductor

Electrolytic copper conductor, Class II, according to BS EN 60228:2005 (previously BS6360) and EN 60228.

2. Insulation

PVC insulation, type TI-1, according to BS 21031-3 and HD21.3S3:1995/A2:2008.

Nominal voltage

450/750 V

Test voltage

2.500 V A.C.

Maximum temperature

70 ºC

Other characteristics

Colours according to UNE-EN 50525-1 and EN 50525-1
Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
CPR Classification according to EN 50575

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)
Class

1x1,5

12,1

2,85

21

Eca

1x2,5

7,41

3,40

30

Eca

1x4

4,61

4,05

47

Eca

1x6

3,08

4,40

64

Eca

1x10

1,83

5,60

104

Eca

1x16

1,15

6,40

146

Eca

1x25

0,727

8,15

249

Eca

1x35

0,524

9,20

339

Eca

1x50

0,387

11,00

470

Eca

1x70

0,268

13,00

698

-

1x95

0,193

15,00

958

-

1x120

0,153

16,30

1.155

-

1x150

0,124

18,35

1.380

-

1x185

0,101

20,60

1.773

-

1x240

0,0775

23,15

2.259

-

Newsletter

captcha 
I declare to be informed that I can exercise rights of access, rectification, cancellation and opposition by addressing RCT via email lopd@rct.es


By checking the box I acknowledge that I have read and I agree with the previous clause *

Newsletter 2

Los datos recogidos en el siguiente formulario los utilizaremos para enviar comunicaciones sobre nuestros productos o servicios. Usamos Elastic Email como nuestro servicio de Marketing Automation. Al enviar el formulario usted accede a que los datos entregados se transfieran a Elastic Email para ser procesados según sus términos de uso y política de privacidad.