(+34) 976 500 120 | Contact us

05Z1C4Z1-K 300/500 V

05Z1C4Z1-K 300/500 V

Description


This cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575, being those suitable for permanent installations where electromagnetic protection is required to avoid parasitic currents. They are recommended for use in applications for the control and command of inverters, solenoid valves, machine and logic controller start-up, power switches, temperature, current or voltage regulation in motorised valves as well as for installation in computing facilities, airports, road tunnels, railway networks and wherever a low emission of corrosive fumes and gases is required due to fire hazards such as public premises, hospitals, schools and shopping centres.

Reference Standards

UNE 21031-14 and HD 21.14S1

Applications

Suitable for the following installations:
  • Data communication systems
  • Control and signal in electronics
  • Computer systems
  • Weighing equipment, etc.

Industrial Maximum temperature 70 ºC Super slide Flexible Electromagnetic shielding RoHS CPR rated

Technical Characteristics

05Z1C4Z1-K (AS) 300/500 V 05Z1C4Z1-K (AS) 300/500 V
1. Conductor

Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228

2. Insulation

Halogen-free thermoplastic polyolefin, type TI-6 in compliance with UNE 21031-14

3. Metallic armour

70% copper braid on polyester sheet

4. Sheath

Halogen-free thermoplastic polyolefin, type TM-7 in compliance with UNE 21031-14 and HD 21.14S1

Nominal voltage

300/500 V

Test voltage

2.000 V A.C.

Maximum temperature

70 ºC

Other characteristics

Colours according to UNE 21089 and HD 303S2 (colour marking when less than five conductors) and UNE-EN 50334 and EN 50334 (inscription marking when more than five conductors)
Non-flame propagating according to UNE-EN 60332-1-2, EN 60332-1-2 and IEC 60332-1-2
Low halogen content in compliance with IEC 60754
Low emission of corrosive gases in compliance withIEC 60754-1 and 60754-2
Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
CPR classified according to EN 50575

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)
Class

2x1

19,5

7,15

63

Eca

3G0,75

26

6,85

63

Eca

3G1

19,5

7,50

78

Eca

4x1

19,5

8,20

97

Eca

5x0,5

39

7,45

75

Eca

5x0,75

26

8,25

95

Eca

5x1

19,5

8,60

110

Eca

6x0,5

39

8,65

97

Eca

6x0,75

26

9,05

102

Eca

6x1

19,5

9,20

125

Eca

7x0,5

39

8,65

106

Eca

7x0,75

26

9,30

128

Eca

7x1

19,5

9,20

138

Eca

8x0,5

39

9,30

119

Eca

8x0,75

26

10,00

143

Eca

8x1

19,5

10,00

157

Eca

10x0,5

39

10,40

151

Eca

10x0,75

26

10,90

175

Eca

10x1

19,5

10,85

191

Eca

12x0,5

39

11,05

173

Eca

12x0,75

26

11,60

202

Eca

12x1

19,5

11,75

226

Eca

14x0,5

39

11,75

196

Eca

14x0,75

26

12,35

229

Eca

14x1

19,5

12,45

256

Eca

16x0,5

39

12,65

225

Eca

16x0,75

26

13,50

238

Eca

16x1

19,5

13,60

301

Eca

19x0,5

39

13,30

256

Eca

19x0,75

26

14,20

308

Eca

19x1

19,5

14,05

335

Eca

24x0,5

39

14,65

311

Eca

24x0,75

26

15,65

339

Eca

24x1

19,5

15,70

417

Eca

30x0,5

39

16,05

374

Eca

30x1

19,5

17,30

511

Eca

Newsletter

The data gathered through the next form will be used to send communications on our products and services. We use Elastic Email as our marketing automation service. By sending this form you agree with the transfer of the data to Elastic Email to be processed according to their terms of use and privacy policy.

Responsible: Cables RCT S.A.U. Purpose: To manage the submission of information and commercial prospecting. Legitimation: consent of the interested party. Recipients: Data will be transferred to Elastic Email for the automation of the submission. Rights: Access, correction and data erasure, as well as other rights, as explained in the additional information.Additional information on data protection is available on our website’s privacy policy