(+34) 976 500 120 | Contact us

RC4Z1-K (AS) 0,6/1 kV

RC4Z1-K (AS) 0,6/1 kV

Description


These cables comply with the construction product classification criteria according to the EU CPR Regulation 305/2011 and EN 50575, being those indicated for executing permanent installations where electromagnetic protection is required to avoid parasitic currents. Their use is recommended in control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, temperature, intensity or voltage regulation in motorised valves as well as for installations in computer centres, airports, road tunnels, railways and anywhere where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, schools and shopping centres.

Reference Standards

UNE 21123, HD 603 S1 and IEC 60502

Applications

  • Underground supply networks for outdoor lighting installations

They can also be used in the following applications:

  • Underground networks for low voltage distribution
  • Electricity distribution networks
  • Underground service connections
  • Installations in premises with special characteristics
  • Appropriate for installations where greater fire protection is required.

Industrial Outdoor lighting Maximum temperature 90 ºC High Safety Flexible Electromagnetic shielding RoHS CPR rated

Technical Characteristics

RC4Z1-K (AS) 0,6/1 kV RC4Z1-K (AS) 0,6/1 kV
1. Conductor

Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insulation

Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
.

3. Screen

70% copper braid on polyester sheet.

4. Sheath

Thermoplastic polyolefin sheath according to UNE 21123

Nominal voltage

0,6/1 kV

Test voltage

3.500 V A.C.

Maximum temperature

90 ºC

Other characteristics

Colours according to UNE 21089 and HD 303S2 (colour marking when less than five conductors) and UNE-EN 50334 and EN 50334 (inscription marking when more than five conductors)
Non-flame propagating according to UNE-EN 60332-1-2, EN 60332-1-2 and IEC 60332-1-2
Non-fire propagating in accordance with UNE-EN 60332-3-24, EN 60332-3-24 and IEC 60332-3-24
Low halogen content according to IEC 60754-1 and 60754-2
Low corrosive gas emission according to IEC 60754-1 and 60754-2
Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC.
CPR classified according to EN 50575

Dimensions

Section
(mm2)
Resistance
at 20 °C
(Ohm/km)
External
Diameter
(mm)
Weight
(kg/km)
Class

1x16

1,21

8,90

191

Eca

1x25

0,78

10,50

279

Eca

1x35

0,554

11,70

372

Eca

1x50

0,386

13,40

509

Eca

1x70

0,272

15,30

697

Eca

2x1,5

13,3

9,30

99

Eca

2x2,5

7,98

9,90

119

Eca

2x4

4,95

10,30

142

Eca

2x6

3,3

12,00

195

Eca

2x10

1,91

13,80

287

Eca

2x16

1,21

15,50

391

Eca

3G1,5

13,3

9,60

116

Eca

3G2,5

7,98

10,70

156

Eca

3G4

4,95

11,35

196

Eca

3G6

3,3

12,60

258

Eca

3G10

1,91

14,60

384

Eca

3x16

1,21

16,75

548

Eca

4x1,5

13,3

10,30

138

Eca

4x2,5

7,98

11,20

179

Eca

4x4

4,95

12,70

247

Eca

4x6

3,3

14,70

355

Eca

4x10

1,91

15,60

473

Eca

5x1,5

13,3

11,20

162

Eca

5x2,5

7,98

11,85

208

Eca

5x4

4,95

13,30

287

Eca

5x6

3,3

14,90

385

Eca

6x1,5

13,3

11,60

180

Eca

6x2,5

7,98

12,75

240

Eca

7x1,5

13,3

11,60

195

Eca

7x2,5

7,98

12,75

264

Eca

8x2,5

7,98

13,70

296

Eca

10x1,5

13,3

14,60

301

Eca

10x2,5

7,98

14,60

351

Eca

12x1,5

13,3

14,10

294

Eca

12x2,5

7,98

15,55

406

Eca

14x1,5

13,3

14,90

332

Eca

14x2,5

7,98

16,50

462

Eca

16x1,5

13,3

15,80

372

Eca

19x1,5

13,3

16,60

423

Eca

Newsletter

The data gathered through the next form will be used to send communications on our products and services. We use Elastic Email as our marketing automation service. By sending this form you agree with the transfer of the data to Elastic Email to be processed according to their terms of use and privacy policy.

Responsible: Cables RCT S.A.U. Purpose: To manage the submission of information and commercial prospecting. Legitimation: consent of the interested party. Recipients: Data will be transferred to Elastic Email for the automation of the submission. Rights: Access, correction and data erasure, as well as other rights, as explained in the additional information.Additional information on data protection is available on our website’s privacy policy